FZN-27.5 Series Indoor Vacuum Circuit Breaker for Railway Electrification

The FZN-27.5 Indoor Electrified Railway Vacuum Circuit Breaker (hereinafter referred to as the circuit breaker) is a specialized single-phase AC 50Hz indoor distribution device. It is designed for 27.5kV railway power systems to ensure reliable control, protection, and fault isolation in electrified railway networks.
  • FZN-27.5

  • Fenarro

Availability:
Quantity:

Overview


The FZN-27.5 vacuum circuit breaker is widely used in electrified railway traction substations, sectioning posts, and switching stations. With advanced vacuum arc-extinguishing technology, it ensures stable performance, high breaking capacity, and long service life.

This product is engineered to operate under strict environmental and technical requirements, meeting the needs of modern railway power distribution and guaranteeing safe and efficient train operation.


Applications


Electrified railway traction substations

  • Sectioning posts (分区亭) for railway networks

  • Switching stations (开闭所) in railway systems

  • Railway power control and fault protection

  • Single-phase 27.5kV AC railway power systems


Key Features


  • Railway-Specific Design – Optimized for 27.5kV single-phase AC electrified railway systems.

  • High Reliability – Provides stable breaking and fault protection for continuous railway operation.

  • Vacuum Interruption Technology – Ensures arc-free switching with minimal maintenance.

  • Wide Environmental Adaptability – Operates under -25℃ to +40℃ and high humidity conditions.

  • Altitude Options – Available in standard type (≤1000m) and plateau type (≤3000m).

  • Durable & Safe – Resistant to corrosion, explosive gases, and severe pollution.

  • Strong Mechanical Strength – Withstands vibrations and shocks common in railway installations.


Technical Parameters



Operating Mechanism Parameters

Serial No. Item Unit Data
1 Rated Power of Energy - storage Motor W 275
2 Rated Voltage of Energy - storage Motor V AC:110,220; DC:220,110
3 Energy - storage Time at Rated Operating Voltage s ≤15
4 Rated Voltage of Closing Electromagnet (Rated Voltage of Opening Electromagnet from Independent Power Supply) V AC:110,220; DC:220,110
5 Rated Current of Overcurrent Release A 5
6 Rated Current of Auxiliary Switch A AC:10; DC:5
7 Continuous Current Passed by Micro Switch A 2
8 Opening and Closing Current (DC220V, DC110V) A 0.89,1.91

Main Technical Parameters


Serial No. Name Unit Data
1 Rated Voltage kV 27.5
2 Maximum Operating Voltage kV 31.5
3 Rated Insulation Level 1min Power Frequency Withstand Voltage - Ordinary type: 95kV (110kV at disconnecting switch); Reinforced type: 110kV (125kV at disconnecting switch)
Rated Lightning Impulse Withstand Voltage (Peak Value) kV 185kV; 260kV
4 Rated Current A 1250, 2000
5 Rated Short - circuit Breaking Current kA 25, 31.5
6 Number of Rated Short - circuit Breaking Current Operations times 63, 80
7 Rated Short - circuit Making Current (Peak Value) kA 30
8 Rated Short - circuit Duration s 4
9 Rated Operating Sequence - Open - 0.3s - Close - 180s - Close & Open
10 Closing Time ms ≤75
11 Opening Time ms ≤60
12 Rated Capacitor Bank Breaking Current A 630
13 Mechanical Life times 20000
14 Allowable Cumulative Wear Thickness of Moving and Static Contacts mm 4
15 Rated Current Ratio of Current Transformer - 75 - 2000/1.5
16 Overall Dimensions mm Height 1675, Depth 1220, Width 690
17 Total Weight kg 260


FAQ


Q1: What is the voltage level of the FZN-27.5 circuit breaker?

A1: It is designed for 27.5kV single-phase AC, 50Hz railway systems.

Q2: Where can this breaker be installed?
A2: It is mainly used in railway traction substations, sectioning posts, and switching stations.

Q3: Can it operate in high-altitude areas?
A3: Yes, the plateau type can be used at altitudes up to 3000 meters.

Q4: What are the environmental conditions required?
A4: It operates under -25℃ to +40℃, with relative humidity ≤95% (daily average) and ≤90% (monthly average).

Q5: Why is vacuum technology used in this breaker?
A5: Vacuum arc-extinguishing ensures safe, reliable, and maintenance-free operation, which is critical in railway applications.



Previous: 
Next: 
Fenarro has been committed to providing safe,  efficient and convenient solutions for power  systems since 2009

Quick Links

Contact Us
 Email: julien@fenarro.com
  Mobile: +86-13962241135
  Telephone: +86-0512-66728956
  Fax: +86-0512-66728971
    Address: 2009, Bldg 2, No.168 Jingmao road, Suzhou Industrial Park, Suzhou, Jiangsu, China
​Copyright © 2023 Fenarro Power Technology Co., Ltd. All rights reserved. | Sitemap | Privacy Policy | Supported by leadong.com